Multi-line 2 AGC 150 Application Software

You’re about to download Multi-line 2 AGC 150 Application Software

The software you are trying to download is obsolete. Please download the latest version from this page.

You have chosen to download our software.

Within a few seconds, you will receive an email containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

This software applies to the following DEIF products:

You’re about to download 1.18.2

The main changes implemented since the last version are as follows:

PM compatibility: 1.33.0

Corrections:


• It is possible to change time from the service view menu.
• BTB deload could block a DG from executing a load-dependent stop sequence.
• SOLAR: Fixed an issue where PV protocol for Canadian CSI 3PH did not start correctly.
• STORAGE: Sync in AUTO now always work. Bug introduced in version 1.18.0.
• STORAGE: Corrected issue where multiple batteries would not share the allowed charging power when peak shaving charging limit is used.

Ver. Date Description

1.18.2

28/02/2024

PM compatibility: 1.33.0

Corrections:


• It is possible to change time from the service view menu.
• BTB deload could block a DG from executing a load-dependent stop sequence.
• SOLAR: Fixed an issue where PV protocol for Canadian CSI 3PH did not start correctly.
• STORAGE: Sync in AUTO now always work. Bug introduced in version 1.18.0.
• STORAGE: Corrected issue where multiple batteries would not share the allowed charging power when peak shaving charging limit is used.

1.18.1

09/02/2024

PM compatibility: 1.33.0

Corrections

  • STORAGE: Sungrow LC200 Powerstack. PF is now calculated based on ESS P and Q instead of S measurements.
    • STORAGE: For parameter DCdU (channel 17150), the value has been fixed when either BMS output voltage or PCS input voltage are not valid.
    • SOLAR: Corrected SMA Datamanager protocol of how NaN values are handled for P and Q. It now shows 0 kW and 0 kvar.
    • STORAGE: Corrected an issue where a failing write telegram could stop read telegrams from being sent out in the Sungrow Power stack ESS protocol.
    • STORAGE: Corrected Sungrow Powerstack ESS protocol to not send P mode and only send grid mode when stopped. This is to prevent the BESS initializing status from always showing.
    • Password 00000 is no longer valid. The lowest value is set to 00001.
    • A five-digit password is now available on the display.
    • Change of ID to Run with Run one MAINS during active LTO is now working correctly.
    • 'Auto detection' as an input for fluid pump has been removed as it was never supported. Output menu for fuel pump also removed as it is no longer used. Fuel pump, DEF pump and fluid pump outputs can now be set up for CIO 208 outputs.
    • Mains failure hysteresis was overruled in situations where no emergency sources were available. This has been fixed. Furthermore, the precision of the hysteresis calculations has been improved.
    • STORAGE/SOLAR: Corrected issue where any parameter write could reinitialise the Modbus communication if the power meter interface was set to use RTU port 1 instead of RTU port 2.

1.18.0

22/12/2023

PM compatibility: 1.33.0

New features

  • GENSET: Fuel optimisation has been updated to support applications including PV and battery.
  • GENSET: SDU available for genset land (DG).
  • TDU support added. Requires TDU version 1.4.1.0 or higher. Supports genset land, mains, BTB, solar and storage.
  • Added new M-Logic and DI input commands for simulating keyboard buttons digitally.
  • M-Logic: Added M-Logic event counters to the counters tab. This includes: No timer, timer that resets the counters, and timer that resets each individual count per counter.
  • M-Logic: Added events for detecting when a button on the display has been pushed.
  • M-Logic: Added output evaluation to Modbus.
  • Added SPN 92, 512, and 513 to PID1 input and reference (Engine drive, Engine drive marine and DG marine). The SPNs are also added to delta alarm inputs.
  • Added support for the AGC 150 DG to control a Mainspring linear generator package.
  • Added idle run interrupt via start/stop in SEMI-AUTO for genset land, genset hybrid, genset marine, genset PMS lite, engine drive and engine drive marine.
  • Added 3 new RMI custom sensors for multi-inputs.
  • Added default sensor curves in I/O configuration.
  • ATS: Extended with new features, such as support of gensets and ATS breaker (2/3 positions).
  • EIC: Added support for Iveco Stage V NEF67.
  • EIC: Added support for Cummins CM2358.
  • SOLAR/DGHYBRID: Added support for Canadian CSI 3PH
  • SOLAR: Added support for Seven Sensor 3S weather station protocol.
  • SOLAR: Added support for Seven Sensor 3S-TP GHI-Thermopile Pyranometer Weather station protocol.
  • STORAGE: Added support for HoyCore HC01CUBE BMS protocol.
  • STORAGE: Added support for Ningbo Golden Shield BMS protocol
  • STORAGE: Added support for Pixii PowerShaper ESS protocol.
  • STORAGE: Added support for Kehua BCS-B-HUD Series protocol.
  • STORAGE: Added support for Sungrow Powerstack STxxxxkWh 250kW ESS protocol
  • STORAGE: Added support for Delta EPCS 1200/1500/1725 ESS protocol.
  • STORAGE: Added support for Sungrow LC200 ESS protocol.
  • STORAGE: Added support for SinExcel 30P PCS/PDS protocol.
  • STORAGE: Added new option in the drop-down menu for the Dynapower MPS-125. The functionality of the Dynapower CPS-1500 and the Dynapower MPS-125 is the same.
  • STORAGE: Added support for Northvolt VMS ESS protocol.
  • STORAGE: Added support for a battery to act as the isochronous source in grid-forming mode together with gensets in PMS.
  • STORAGE: Added support for Huasu BMS protocol. The TCPIP port number has been updated so it is possible to change the port number on a BMS, ESS and PDS.
  • STORAGE: Added support for HagalOcean PD-003V2 BMS protocol.
  • STORAGE: Added support for Sunwoda Main BCMU protocol.
  • STORAGE: Added support for Sunwoda BCMU protocol.
  • STORAGE: Added support for KGooer BMS protocol.
  • STORAGE/SOLAR: Added support for using CAT EMCP 4 controllers directly as power meter.
  • STORAGE/SOLAR: Updated openPMS and single controller plants to support deloading of external gensets in island applications, when the start/stop digital output functionality is used.
  • STORAGE/SOLAR: PV taking maximum load. Accept PV to increase the power and stop genset, even if loads are bigger than BESS nominal size.
  • STORAGE/SOLAR: Added parameters 2671 and 2672 (P ref. const. gain & P ref. dyn. gain), which allows the user to add a local constant or dynamic gain to the power reference sent to the inverter.

Changes

  • Changed alarm list text from "Bool eval" to "Val" and values "0" / "1" to "low" / "high".
  • STORAGE: Updated the Ausar ESS protocol to make more data available and acknowledge faults in the system when the "ESS shutdown" alarm is acknowledged.
  • EIC: Added GTACP (0xFE05, SPN2452/2460) to Caterpillar generic and Perkins generic.
  • SOLAR/DGHYBRID: Changed control registers for Power One PV protocol.
  • DG: Digital inputs 47, 48, 49 and 50 are now always visible in the I/O setup menu.
  • Option S1 controllers can now be changed to the following controller types from the display: Standalone DG, Engine drive, ATS and Remote display.
  • The shutdown override inhibit is now configurable for the following alarms: #1130 I>> 1, #3490 Emergency STOP, #4510 Overspeed 1, #4520 Overspeed 2 and #7600 EIC overspeed.
  • STORAGE: Updated the Dynapower CPS/MPS ESS protocol to always be in off-grid mode if parameter 2801 is enabled. Also added droop curve adjustments to reach requested off-grid power set points.
  • The spinning reserve stop hysteresis is now calculated based on the nominal power on busbar after next DG to stop.
  • HYBRID: Internal AC, P, Q and S power values averaged for the display and Modbus. Can be used for plant logic by selection in menu 7021.
  • EIC: Added John Deere DPF stages as M-Logic events.
  • PMS lite control between ISLAND/CanB ON and SingleDg with Mains/CanB OFF added via I/O and M-Logic.
  • PMS Lite: Added genset DUTY in AUTO.

Corrections

  • PMS priority update in 32 DG applications now working correctly.
  • Even if the DAVR controls setting was OFF, connecting to a Nidec D550 without the S4 option would generate an 'Illegal DAVR' alarm. This has been fixed.
  • The start sequence could not be cancelled between start attempts in SEMI-AUTO. This has been fixed.
  • AGC 150 Remote display experienced occasional communication loss when it was in sync screen. This has been fixed.
  • SOLAR/STORAGE: Split the "Secure Elite XXX" power meter into two protocols: "Secure Elite 100/300" and "Secure Elite 440/500". This was done to correct a power scaling issue.
  • SOLAR/DGHYBRID: Inverted the reactive power set point in the Sofar G3 PV protocol.
  • Using a multi-input as an external reference for regulation no longer needs a power cycle of the controller to work.
  • If a DG in PMS has an "missing all units" alarm active, it will now shutdown if its auto start signal is deactivated.
  • STORAGE: Scaling of P/Q reference and charge/discharge capacity corrected in the Matter Energy PCS protocol.
  • SOLAR/STORAGE: Fixed an issue where it was not possible to switch to application drawing 4 through Modbus Or M-Logic.
  • Peak shaving working again. Compromised in version 1.17.0.
  • Alarms with the shutdown override inhibit are now shown in the display and recorded in the alarm log if the alarm becomes active, but the fail class is still inhibited.
  • STORAGE: VSG mode changed for Sungrow LC100. Now always send, for example, F=50 and U=400, and only use P and Q set point whether the PCS is running alone or paralleling with other sources.
  • Power capacity is now requested correctly in an AMF application to start the required number of DGs and close the tie breaker (TB).
  • STORAGE: VSG updated for Sungrow LC100, LC200, Powerstack and STXXXCP-50HP: P and Q set points are used whether the PCS is running alone or paralleling with other sources.
  • STORAGE: Updated the Danfoss Vacon NXP ESS protocol, so a sync of either ESB or MB is possible.
  • SOLAR/STORAGE: Fixed scaling of the ESS AC measurements in emulation when AC scales other than 100-25000 V are used and the ESB is open.
  • Auto calculation of multi-starts with fuel optimisation is now working before the TB is closed.
  • STORAGE: Corrected the start sequence of the Sicon PCS to only send a start command once.

1.17.2

14/09/2023

PM compatibility: 1.30.1

Corrections

• SOLAR/DGHYBRID: Corrected an issue where the extended Modbus TCP/IP, would use the control ID to initialise SunSpec, instead of the monitoring ID.
• SOLAR/DGHYBRID: Fixed an issue where a multiple write telegram together with only one monitoring telegram, would only send out the monitoring telegram.
• Fixed an issue where the display LED lamps would flash faster during breaker synchronisation.
• In a LTO multi-start setup, a number of multi-start gensets did not always start to synchronise at the same time. This has been fixed. PM compatibility version raised.
• Status text 'NOT IN MAN or SEMI' no longer shown in AUTO. V0108 activated.

1.17.1

21/07/2023

PM compatibility: 1.30.0

Corrections

  • Measure viewline 5 working again.
  • Battery log is now correctly updated when the relay output of the battery test function is set to 'limits'.
  • The load shedding and adding timers were not working as a time hysteresis. This has been fixed.
  • PMS lite: The available power alarm (menu 8540) was calculated incorrectly. This has been fixed.
  • PMS lite: The ID not available alarm (menu 8511) would be activated when changing from a manually chosen ID to a different but free ID. This has been fixed.

1.17.0

30/06/2023

PM compatibility: 1.30.0

New features

  • Multi-start switch to minimum number to run right after first GB closes via configuration in menu 8360.
  • LD stop without delay available via configuration in menu 8350.
  • SOLAR/DGHYBRID: Added new Modbus TCP/IP extended setup of the ASC 150 Solar and AGC 150 DG HYRBID.
  • SOLAR/STORAGE: Added open PMS functionality.
  • SOLAR: Added support for Power One PV protocol.
  • STORAGE: Added Eastron SDM630CMT powermeter protocol.
  • Added new Modbus area for alarm list monitoring.
  • STORAGE: Added parameters 17161 and 17163. If the parameters are enabled, they will overwrite the value of the maximum charge voltage and minimum discharge voltage read from the BMS.
  • SOLAR/DGHYBRID: Added Solis logger NISE PV protocol.
  • Added option to ignore certain SPN rules from the USW.
  • DG/PMS Lite: Added supervision view-line for DG and PMS Lite.
  • SOLAR/DGHYBRID: Added Kehua SPI PV protocol.

Changes

  • SOLAR: Fixed Deye PV protocol issue.
  • STORAGE: Added max, min and avg. module temperature read-out for the Polarium BMS.
  • SOLAR: An ASC 150 SOLAR with the Premium option enabled now supports up to 32 PV inverters when using Modbus TCP/IP.
  • STORAGE: Changed the status reading of the Ausar MAE v4 ESS protocol to only cause a shutdown at critical faults and no longer minor faults.
  • STORAGE: The Ausar MAE v4 ESS protocol now supports the charging mode for low ripple current, which is turned on by the custom input to ESS in M-Logic.
  • Manual PMS priority update via digital input or M-Logic only occurs on one DG within 10 seconds.
  • SOLAR/STORAGE: Changed name of MTR protocol from MTR-3 to MTR-3/4.
  • STORAGE: RCCR inputs and outputs can now operate with negative P set points.
  • DG/PMS Lite: Updated the function list for digital outputs to include controller modes.
  • Possible to have special descriptions of specific SPN/FMI combinations for Volvo Penta EMS2 and EMS 2.4.
  • Possible to have a second ECU for Volvo Penta EMS2 and EMS 2.4.

Corrections

  • STORAGE: Fixed Yingbo Droop U/F protocol issue.
  • STORAGE: Corrected scaling issue with read current values from the GOLD BMS protocol.
  • HYBRID/SOLAR: Fixed broadcast write Modbus message for reactive power (Q) for the Matter PV protocol.

1.16.1

30/05/2023

PM compatibility: 1.29.0

Corrections:

  • EIC: Aftertreatment 1 DPF Time since Last Active Regeneration (SPN 3721) has been corrected.

1.16.0

16/05/2023

PM compatibility: 1.29.0

New features:

  • Added new device type, AGC 150 DG PMS lite.
  • EIC: Added support of Scania S8 Industrial.
  • EIC: Added support of ANGLE.
  • EIC: Added support of Jing Guan.
  • EIC: Added support of JCB 430/448 Stage V.
  • EIC: Added M-Logic outputs to inhibit DM1 protection, yellow, red and malfunction lamp alarms.
  • EIC: Added VTAs on EIC malfunction and protection alarms.
  • EIC: Added After treatment DPF Time since Last Regeneration to the display and Modbus.
  • SOLAR: Added support for Ingeteam 3Play ABS PV protocol.
  • SOLAR: Added support for Sofar -G3 PV protocol.
  • STORAGE: Added support for CATL liquid cooled BMS protocol.
  • STORAGE: Added support for Megarevo MPS protocol.
  • STORAGE: Added support for Polarium BMS protocol.
  • STORAGE: Added support for GTZKNE FX34 BMS protocol.
  • STORAGE: Added support for Yingbo PCS protocol.
  • STORAGE: Added support for Oztek OZpcs-RS40 PCS protocol.
  • STORAGE: Added support for SinExcel PWS2 30K PCS protocol.
  • STORAGE: Added Battery SOC active threshold levels in M-Logic.
  • MAINS: Added negative and zero sequence alarms.

Changes:

  • M-Logic and digital input function to allow safe regeneration.
  • Sinexcel PDS has been updated to read the power of a maximum of 8 DC strings.
  • EIC: FPT Stage V Low oil pressure alarm can only be triggered while running. Added new M-Logic event for DEF warnings.
  • EIC: Updated DM1 and DM2 headline log texts.
  • EIC: Stage V: Added the four AT regeneration states to the existing view-line.
  • EIC: Added auto acknowledge feature for engine comms alarm, channel 7570.
  • SOLAR: Changed the name of existing Ingeteam 3Play PV protocol to "Ingeteam 3Play ABI".
  • STORAGE: Changed the name of the existing CATL BMS protocol to "CATL air cooled BMS".
  • STORAGE: Changed the Atess protocol to only send start/stop commands when the run state has changed.
  • STORAGE: Changed the name of the existing SinExcel ESS protocol to "SinExcel PWS1".
  • Updated the alarm list to include alarm value, set point and fail class.
  • Added enable to the 3 inputs in the General PIDs (GPID) in the M-Logic commands.
  • Reference Set point, Min, Max and Offset added to all four General PIDs (GPIDs).
  • STORAGE: Added support for Yingbo VSG mode.

Corrections

  • Corrected issue where PV did not produce the correct Q to meet the requested grid PF, when the plant operates with a voltage-based droop and the mains voltage changes.
  • STORAGE: Fixed Jinko protocol scaling of PQ and current limits. Start/stop cmd issue also fixed.
  • DG HYBRID/STORAGE/SOLAR: When using ext. GB/ESB/PVB and MB, if the functions of the default digital inputs for GB/PVB/ESB and MB feedbacks are set to "Not used", they do not influence the breaker position feedbacks.
  • Corrected issue where service view timers froze in certain circumstances.
  • Corrected issue where output 14, output 16 and output 18 (when the device is an AGC 150 ATS) would reset after a power cycle, when the breakers (MB, GB, BTB) are continuous breakers.
  • Added active/disable feature for Easy connect in the output tab in M-Logic.
  • STORAGE: Corrected issue where in a PMS plant with PV charging enabled and the PV running with Instant P-Max enabled and set to no sensor, changing the SOC from a value less than SOC max to a value above it, would lead to the battery discharging.
  • STORAGE: Corrected issue where, when optimal DG load is enabled the battery would not charge from the PV even though the PV was not fully loaded.

1.15.1

03/04/2023

PM compatibility: 1.29.0

Corrections:

  • The breaker ext. tripped alarm is no longer triggered when reconfiguring a no breaker application to an application with a breaker.
  • STORAGE: Corrected issue where a Sinexcel PCS without VSG would switch from V/f mode to P/Q mode during ESB synchronisation resulting in sync failure.
  • MAINS: Corrected issue where PV did not produce the correct Q based on its capability curve and P/Q cap. limit in PMS applications.
  • STORAGE/SOLAR: Using M-Logic for external PVB/ESB feedback is now possible when emulation is active.
  • Power meters in application supervision are no longer shown on external BTB.
  • Multi-input scaling issue on custom curve. It now shows the correct value compared to the curve it should follow.
  • During a transfer of ground relay, a DG that was not suited for closing its ground relay, could briefly close it and then quickly open it again. This has been fixed.
  • STORAGE/SOLAR: Incorrect handling of digital input functions, "Remote start/stop" and "Remote PVB/ESB on/off" corrected.
  • When the energy counter "kvarh" was on a viewline on the controller, the corresponding viewlines on other pages showed the last variable incorrectly. With this the costumer got the wrong information on the controller. This has been fixed.
  • DG HYBRID: PV is no longer prevented from starting in applications where no GB is configured, as long as there is voltage on the busbar.
  • DG: Fixed menu for multi-input 20 failing to display viewing of curve set points.
  • Engine Drive/Engine Drive Marine: Support of PWM output using PID1 (engine speed).
  • DVC "controls OFF" only sent few initial data after loss of communication.
  • Power ramp 1 automatic shift to power ramp 2 working correctly.

1.15.0

10/02/2023

PM compatibility: 1.29.0

New features:

  • New device type ASC 150 Solar added, supporting both single controller and PMS applications.
  • Added a pop-up before changing controller type to inform the user that everything is being reset.
  • GENSET: Added I/O setup menu for configuring internal and external I/O (CIO), including multi inputs and CIO-308 from display.
  • HYBRID: Support for SolarEdge PPC PV protocol added.
  • STORAGE: Support for DEIF MIB8000 power meter added.
  • STORAGE: Support for Eastron Smart X96 power meter added.
  • STORAGE: Support for EPC Power PCS protocol added.
  • STORAGE: Added Jinko PCS protocol.
  • STORAGE: Parameter 2810 added to the ASC-4 Battery. This can be used to configure a timeout period after the last transmitted heartbeat signal before the PCS activates an error (only for supported ESS protocols).
  • STORAGE: Parameters 2805 & 2806 have been added to support a user-adjustable offset to the droop curves used for delta frequency and delta voltage calculation when a genset or mains is connected.
  • STORAGE: When the S10 option is disabled and a user tries to change the controller type to ASC 150 storage, a pop-up is shown on the display to tell the user that the S10 option is disabled.
  • STORAGE: Added BMSer Technology BMS protocol.
  • STORAGE: Added Narada w Ctrl BMS protocol.
  • STORAGE: Support for Dynapower CPS-1500 PCS protocol added.
  • EIC: Added FPT Stage V Turbo heat protection M-Logic event.
  • EIC: Added Scania S8 safe regeneration signal M-Logic output
  • EIC: Added safe regeneration status M-Logic event.
  • EIC: Added support of Caterpillar ADEM6.
  • EIC: Updated Iveco Stage V with new alarms, M-Logic events and symbol handling.
  • EIC: Added a new view to check the status of a regeneration request from the ECU. Added new M-Logic events to Deutz EMR5 Stage V.
  • EIC: Added new view for engine icons. Added new icons for FPT Stage V.
  • STORAGE: Support for Ausar MAE version A04. ESS protocol added.
  • STORAGE: Added new M-Logic output and event to give the user the option to manually activate boost charging in supported systems.
  • STORAGE: Parameters 17201, 17202 and 17203 have been added to set a PDS spinning reserve value. This sets the percentage of the produced PDS power which should be reserved locally as extra available battery discharge capacity.
  • HYBRID: Support for using M-Logic for handling external GB, ESB and PVB added.
  • PLC-controlled PMS. When in auto mode and this mode is activated using M-Logic, a user can control the controller using a PLC (for example, digital inputs).
  • TEM analog transducer output added in menu 5750.
  • STORAGE: Added SICON PCS protocol.
  • EIC: Added support of Kohler KDI 3404 Stage V.
  • Added a new small text version of the synchroniser view.
  • STORAGE: Added support for Gold BMS protocol.

Changes:

  • HYBRID: Updated Huawei V.3 PV Protocol to send a start/stop command to the inverter based on the controller status.
  • Improved texts to PID regulator: Kp (Gain), Ti (Stability), Td (Derivative).
  • M-Logic event for "CBE excitation start level (rpm) reached" added.
  • M-Logic event for Load Dependent Start/Stop 2 ON/OFF status added.
  • M-Logic command for Load Dependent Start/Stop 2 ON/OFF control added.
  • Averaged P and Q (introduced in version 1.14.0) can now be used for load sharing (menu 9267).
  • STORAGE: Sungrow LC100 Utility LFP and STxxxCP50-HV ESS protocols will now use delta frequency and voltage regulation when operating in VSG on-grid mode.
  • Translations: Two languages were removed, and texts per translation (languages) were increased.
  • EIC: Added a new text on the Aftertreatment viewline when the ECU is not connected or responding.
  • EIC: Inhibit DM1 lamp alarm if engine is not running and no valid SPN is available.

Corrections:

  • STORAGE: Corrected the issue where multiple batteries operating in island with PVs make the PVs overproduce power compared to what the batteries were asked to charge.
  • The power ramp module initiates its ramp faster.
  • AGC 150 renamed text "EIC configuration" to "ECU configuration".
  • AGC 150 EIC configuration moved from GOVC to Engine subfolder in USW and display.
  • MAINS unit power measured with open MB no longer added to available power in DG.
  • Hz/V OK alarm timer (4560) no longer started in CBE, when cooldown is active, and excitation is removed.
  • STORAGE: Corrected Modbus issue with DEIF MIC 4000 power meter protocol.
  • EIC: LiveLink is now working when used with PSI.
  • STORAGE: Corrected issue where parameter 2741 for delaying regulation after start signal did not work for charging set points.
  • Change of breaker feedback is remembered after a power cycle.
  • Corrected issue where specific PV spinning reserve values in a plant with a battery and DGs could cause genset start/stop looping.
  • Corrected issues where PV spinning reserve values in a plant with a battery, PV, Mains and DGs would not start and stop the gensets at the correct available power.
  • STORAGE: ASC 150 Storage was able to close the MB with an unsupported application alarm active.
  • Busbar emulation improved.
  • STORAGE: Corrected issue where a battery still would try to charge fully from a PV which was deloading to stop.
  • Mains failure hysteresis is now respected if one of the OK timers is running at the same time as the OK condition is reached.
  • HYBRID: It is now possible to choose P & Q measurement values from Modbus communication when in emulation.
  • Measurements P-L2, S-L1, S-L2, S-L3 readout in display scaled correctly.
  • TB remains closed even though a PV is the only power source connected to the busbar.
  • STORAGE: Corrected the calculation of frequency set point for ESB sync and MB back sync.
  • STORAGE: Corrected issue where a battery would stop in a PMS auto application if the internal mode of the ASC was set to "No dispatch" instead of only offloading when other voltage sources were connected to the busbar.

1.14.0

11/11/2022

PM compatibility: 1.27.0

New features:

  • ASC 150 Storage, now with power management support.
  • AGC 150 DG Easy connect compatibility with ASC 150 Storage.
  • Added GOV and AVR outputs to trending.
  • Inverter and busbar V/f measurements from inverter communication supported on all protocols on ASC 150.

Changes:

  • Updated Schneider CL 30/33/50/60 PV protocol to only read 6 DC string current values to be compatible with the newest Schneider firmware.
  • Configurable averaging of AC measurements for readout on display and Modbus in menu 9260.

Corrections:

  • Corrected that top viewline was flickering when external power setpoint is active. This is also present when the system is on power management.
  • BTB dividing sections sequence is now working correctly in AMF situations.
  • Corrected issue with ext comm errors always high, when rs485 port is configured as master.
  • CANShare initialisation no longer requires a power cycle to act correctly.

1.13.0

21/10/2022

PM compatibility: 1.26.0

New features:

1- New device type AGC 150 ATS added.
2- Support for DEIF DVC 350.
3- Automatic adblue refill and a generic fluid refill.
4- Automatic adblue refill: System for monitoring and start/stop filling a diesel exhaust fluid tank.
5- Fluid fill: System for monitoring and start/stop filling a fluid tank.
6- PMS mode update from ASC supported.
7- Added average for multi-input and MPU on Modbus and display.
8- New parameter #6234 GB reclose attempts added.
9- Support for M-Logic shortcuts via shortcut menu.
10- Five new LED lamp view lines.
11- Added shortcut for engine regeneration.
12- Added shortcut for ECU diagnose.
13- Virtual event toggles when using Modbus. Created new virtual switch event that stays high when put high in Modbus and M-Logic.
14- EIC: Added support of Jichai JC15T JG protocol.
15- EIC: Added support of Cummins CM2850.
16- EIC: Added support of Cummins CM2350.
17- EIC: Added support of Cummins CM2880.
18- EIC: Added support of Weichai E6.
19- HYBRID: Support for INVT XG series PV protocol added.
20- HYBRID: Support for Matter Energy PV protocol added.
21- HYBRID: Support for external MB operation added to DG HYBRID (option S1) and ASC 150 added. Ext. MB feedback can also now be set through M-Logic.

Changes:

1- The low speed digital input and idle start/stop timers can now be used together.
2- Tier 4 icons view now display a frame where icons will be shown.
3- Changed overload alarm 5 (1490) to low load alarm.
4- In CANshare mode, ID and total number of gensets now shown on lower tiny line in measure views.
5- The default application configuration name has been updated.
6- Gov renamed to speed control in menu structure.
7- Common names in digital inputs (from 1.12.0) used in menu system on display.

Corrections:

1- PID force min/max is now working when offset is used.

1.12.1

30/09/2022

PM compatibility: 1.25.0

Corrections:

  • Modbus broadcast telegrams now works again when communicating with multiple PV inverters on the DGHYBRID controller.
  • Corrected issue where an external Modbus RTU master sending telegrams into a RTU port also configured as a master on the AGC150 DGHYBRID controller could cause a restart.
  • Corrected the Modbus addresses used for P/Q ref. and ACP/ACQ reading for the SMA Data Manager PV protocol.

1.12.0

12/09/2022

PM compatibility: 1.25.0

New features:

  • New device type ASC 150 Storage added.
  • External controlled MB available on stand-alone (option S1) generator variants (LAND, MARINE, HYBRID).
  • CAN B protocol changed with M-Logic to PM and CanShare.
  • Oneshot logic in M-Logic.
  • Current alarms for 4th CT measurement added. Menu 7420 and 7430.
  • CBE re-run failure alarm added. Menu 2230.
  • Text tree structure in USW translation added.
  • List with common names for digital inputs.
  • EIC: Added FPT Stage V SPN/FMI fault codes.
  • EIC: Added support of KWG ISO5 isolation monitor.
  • EIC: Added support of QiYao Gas.
  • EIC: Added support of Doosan stage V protocol.
  • HYBRID: Added support for Thea PV protocol.
  • HYBRID: Added support for Deye SUN 30-50K-G03 PV protocol (Unicast only).

Changes:

  • I/O status added to trending in USW.
  • Busbar block handling in PMS now allowed to let the system (DG, MAINS etc) run even though any breaker has position failure.
  • EIC: Scania S8 is now showing regeneration active symbol when manual regeneration is active.
  • Reduced number of languages to 10.

Corrections:

  • #7804 DAVR bias range now works correctly for DVC 550 and D550 DAVRs.
  • Update of modes on all controllers in a PMS application has been made more robust.
  • PMS island load sharing would not work correctly when #9030 Scaling was set to something other than default. This has been corrected. PMS asymmetrical load sharing in island also corrected when using a different scaling than default.
  • In rare cases connected DGs could trip and stop, when units disconnected from PM reconnects.
  • Diagnostics timer (#6701) is now working.
  • Channel numbers 7720+7730+7731 in USW aligned with channel numbers in display, so all is 7721+7731+7732 to avoid confusion.
  • CBE re-run no longer closes generator breaker directly on black busbar with cooldown control set to excitation ON.
  • Static synchronising works in 3W3 coupling.
  • Shutdown override did not work correctly when the failclass of an alarm was set to GB trip, GB trip + stop or shutdown. This has been fixed.

1.11.0

11/07/2022

PM compatibility: 1.25.0

New features:

  • JC15D Weifu alarm texts added to DM1 log.
  • Added support of JC15D WYS EIC protocol.
  • Added support of JC190 EIC protocol.
  • Added support of Bosch EDC17CV54TMTL EIC protocol.
  • Added configurable TSC1 transmission rate and checksum/counter for Generic J1939.
  • Added support of Xichai EIC protocol.
  • Enable/disable alarm ack. via J1939 (DM11).
  • Added support of Kubota EIC protocol.
  • Extended RMI 20 Points in multi-inputs.
  • Extended mA 17 Points in multi-inputs.
  • Hybrid Supervision view on controller display added.
  • Parameter to block nominal settings changed.
  • Extended EIC wait to start (preheat) support. Introduced M-Logic command to inhibit wait to start.
  • View line: Added kW per phase (L1, L2, L3).
  • View line: Added kW per phase in percent (L1, L2, L3).
  • View line: Added Power factor per phase (L1, L2, L3).
  • EIC: Added support of Scania EMS2 S8 HC Evaporation Status in M-logic and view.
  • View line: Added Charge Alternator Voltage - D plus voltage.
  • Automatic speed detection view line.
  • Automatic oil pressure view line.
  • Automatic water temperature view line.
  • Automatic fuel level detection view line.
  • Multi-input view lines change text with RMI selected.
  • Added RMI Custom to multi-input input type.

Changes:

  • J1939 protocol "Jichai" renamed to "JC15D Weifu".
  • FPT/Iveco Stage V updated.
  • Default views updated.
  • Default values for multi-input.

Corrections:

  • N + X ON/OFF via digital input or M-Logic corrected.
  • Busbar measurement working correct in single and split phase with BB set to 3W3.
  • A genset will now charge a battery with the correct amount during negative PMS set points.
  • A genset will now calculate the correct power reference if a battery operating as a energy source is charging from excess PV power.
  • A running DG with its GB closed could react to invalid power management data when changing from a single DG application to a standard application.
  • DVC 550/D550: Stator current limitation events in M-Logic did not work.
  • A mains could issue a start signal to DGs based on invalid power management data when a BTB was power cycled.
  • AOP-2 button emulation from USW-3 working.
  • Fault in PDB. Alarm Relay ND and NE text swap. I/O setup is wrong; parameter is correct.
  • External generator breaker configuration on DGs corrected so GB relays are configurable.
  • Configuration of running detection timer is now working from display.

1.10.4

30/06/2022

PM compatibility: 1.25.0

Corrections:

  • Corrected an issue where two or more DGs could end up with the same priority.

1.10.3

01/06/2022

PM compatibility: 1.25.0

Corrections:

  • Engine Drive Marine, Marine DG ISLAND: Remote Start and Remote Stop working.
  • MARINE: Status text updates.
  • MARINE: TEST function now stops the engine when TEST is finalised.
  • MARINE: Idle run stops engine correct when using Low speed or timer.

1.10.2

19/04/2022

PM compatibility: 1.25.0

Corrections:

  • GOV output was sometimes raising to 100% when GB was closed with static sync. This has been fixed.
  • Deutz EMR Stage V stop telegram corrected.

1.10.1

18/03/2022

PM compatibility: 1.25.0

Corrections:

  • EIC autoviews is not deleted doing power up.
  • EIC Deutz EMR Stage V: DEF level is shown and SPN5246 is mapped to m-logic eic derate active.
  • MARINE EDG: GB stays closed in SEMI mode even though the STOP button is pressed.
  • Translation issue seen when loading multiple languages is corrected.

1.10.0

28/02/2022

PM compatibility: 1.25.0

New features:

  • Controller types 'Genset Marine' and 'Engine Drive Marine' added.
  • DG HYBRID: Growatt CP100-CP250 & Growatt CP500-CP2250 PV protocols added.
  • DG HYBRID: Growatt Mac, Max & Mid series PV protocol added.
  • RMI Water temperature extended ranges.
  • DG HYBRID: SMA Data Manager PV protocol added.
  • Support of Perkins Stage V 120xJ (SU, VM) EIC protocol added.
  • Support of Deutz EMR5 Stage V EIC protocol added.
  • Activate/deactivate spinning reserve via M-Logic added.

Changes:

  • DG HYBRID: Renamed "Growatt" PV protocol to "Growatt UE-series".

Corrections:

  • DG HYBRID: Q share and DG cosphi limits now works correctly compared to the cosphi of the DG.
  • Increased measurement inaccuracy at changing frequency could be seen infrequently.
  • AMF Overlap is now working when modeshift is used with two or more MAINS units in power management.
  • Numbers of view pages is updated correctly.

1.09.1

08/02/2022

PM compatibility: 1.24.2

Corrections:

  • Logs stored correctly to work after a power cycle.

1.09.0

14/12/2021

PM compatibility: 1.24.2

New features:

  • DG HYBRID: Added GoodWe HT Series PV protocol.
  • DG HYBRID: Huawei V.3 PV protocol added. This protocol replaces all older Huawei protocols for newer inverter firmware versions.
  • M-Logic input events for auto start command from any DG, any MAINS or any BATTERY in Plant.
  • RPM based on calculation from the AC frequency reading.
  • DG HYBRID: Added Havells 1-40kw PV protocol.
  • DG HYBRID: Added Havells 50-70kw PV protocol.
  • DG HYBRID: Added Sofar Solar 1-40kw PV protocol.
  • DG HYBRID: Added Sofar Solar 50-70kw PV protocol.
  • DG HYBRID: Added Chint (CPS) Boost 100-250kW PV protocol.
  • M-Logic command for turning display backlight and all LEDs OFF added.

Changes:

  • PM-id added to lower info line together with page-number and PM-prio.
  • Multi-input wire-break setup: Delay, Auto acknowledge and Inhibit added.

Corrections:

  • No ASC-4 PV irradiance sensor could make AGC DG's provide inadequate power for mains power export.
  • Cosphi superior set points now work with only PV or Battery units on the busbar together with a AGC 150 mains.
  • EIC and CIO communication can run at the same time again.

1.08.1

01/12/2021

PM compatibility: 1.24.2

Corrections:

  • Minimum load was not respected when using droop curve 1.
  • 'Guided view with genset' now shows start/stop buttons equal on all DG's in an ISLAND PMS setup.
  • DG HYBRID: Added correct scaling for P/Q reference and changed the Broadcast ID to be 0xFF in the Polycab 50-60kW PV protocol.
  • EIC generic J1939: Missing data readings (SPN 1119 and 1180) added to protocol.

1.08.0

11/11/2021

PM compatibility: 1.24.2

New features:

  • PMS redundancy via Ethernet added.
  • DG HYBRID: Added Modbus TCP/IP master communication support for PV and weather Modbus interfaces.
  • DG HYBRID: New weather protocol for POA and BOM reading: Kipp & Zonen - RT1 Smart Rooftop Monitoring System.
  • Added support of Cummins KTA19 EIC protocol.
  • Added electrical load telegram to Caterpillar engine I/F.
  • DG HYBRID: Havells 80-136kW PV protocol added.
  • DG HYBRID: Polycab 50-60kW PV protocol added.
  • DG HYBRID: FIMER PVS980 PV protocol added.
  • Power ramp improved.
  • Added support of Jichai EIC protocol.
  • Added supported ECU types.
  • Added Preheat functionality for Perkins Stage V.
  • NTP Support added.

Changes:

  • Maximum timer extended to 3200.0 s on a number of protections (AC, digital inputs, MPU, EIC).

Corrections:

  • QSPI communication speed corrected.
  • Self-check error 49 during read of log.
  • DG HYBRID: EVVO PV active power control corrected.
  • ISLAND deload of last GB now works as expected, so the GB opens when the frequency has dropped 0.5 Hz below nominal.
  • Deload TB before GB opens function works correctly in PEAK SHAVING.
  • FULL TEST available again. Was taken out in 1.04.2.
  • DG HYBRID: POA and other weather-station values can now be written with DEIF OPEN communication.
  • Analogue output limits for transducer output corrected, so min/max on input is reflected directly to output limits.
  • PMS priority change via M-Logic or Modbus now works correctly.
  • Fast OverCurrent max set point reduced from 350 % to 300 % due to alignment with data sheet. Backward compatibility compromised.
  • If the ground relay was enabled and the application configuration was a non-PMS single DG, the GB would not open when deloaded.
  • df/dt now operates on the mains side measurements.
  • Configuration of outputs 15-18 is now correct after power cycle.
  • Alarm texts are shown when the alarm is reviewed from CAT EMCP.

1.07.0

21/06/2021

PM compatibility: 1.24.1.

New features:

  • Multiple busbars on CANshare is implemented, and 64 BTBs are available.
  • Remote display functionality is added. This includes a new controller type.
  • Reverse power: 3 AC protections are added.
  • Support of Perkins Stage V EIC protocol is added.

Changes:

  • MAINS connection are now allowed in the STAND ALONE variant and none GB or external GB.
  • DG HYBRID: PV semi start/stop commands are added to M-Logic and to the Modbus commands.
  • Weichai gas EIC protocol is updated with new data readings.

Corrections:

  • "Fuel optimization" and "Fuel optimization + running hours" are now working with percent values.
  • EIC transmission rate stability is improved.
  • DG HYBRID: It is no longer possible for the unit to send negative P-ref set points to a PV inverter.
  • Power emulation for AGC 150 with Option S1 is now calculated and shown correctly.
  • DG HYBRID: Corrected an issue where Emulation PV was not able to start with PV protocol set to OFF.
  • DG HYBRID: Corrected an issue where Goodwe DT and MT protocols would show negative ACP at values above 32768 W.

1.06.1

06/05/2021

Version 1.06.1 based on 1.06.0.

PM compatibility: 1.23.0.

Corrections:

  • Limit events is added in M-Logic for Extended M-Logic Alarms.
  • DVC 550/D550 now works with the EIC protocol Volvo Penta EMS 2.4.

1.06.0

29/04/2021

PM compatibility: 1.23.0.

New features:

  • DG HYBRID: Added new parameter #17132 "Curtail threshold".
  • Added support for John Deere Stage V EIC protocol.
  • Added support for Isuzu EIC protocol.
  • Added new parameter #6176 "Not running delay". Can be used as a hysteresis if the running feedback unexpectedly falls under the running detection level.
  • Added support for Kohler EIC protocol.
  • Added support for FPT + Iveco Stage V EIC protocol.
  • Added four new M-Logic alarms with extended delay in menu 3620-3650.
  • Added Event log entry when the application setup changes.
  • DG HYBRID: Added monitoring tool for Modbus master communication within the service view under communication analysis.
  • Added new GOV and AVR step test in parameter group #2970.
  • DG HYBRID: Added support for Sungrow Logger 1000 PV protocol.
  • DG HYBRID: Added support for Growatt PV protocol.
  • Added keyswitch for Diesel engine.
  • Added new controller type 'Engine Drive'.
    • Added MPU and EIC speed as PID1 input.
    • Added EIC as PID1 output.
    • Added digital input functions to control PID1 output (Semi manual mode).
    • Added ramp functionality for PID1.
    • Added new shortcut menu (Engine shortcuts).
  • DG HYBRID: Added support of PV breaker.
  • EIC speed (SPN 190) and MPU speed added to delta alarms.

Changes:

  • Default views for DG are changed.
  • Engine I/F list is reorganized in alphabetical order.
  • Fuel pump logic is available for Stand-alone and Core software versions.
  • The SunSpec identifying information shown in the display is improved.
  • PV protocols are listed in alphabetic order in the display and the USW.
  • DG HYBRID: Added fallback timer for power limit on SunSpec (Parameter 17180).
  • Minimum timer for AC busbar alarms is decreased from 0.1 to 0.04 seconds.
  • Text is changed in the shortcut menu.
  • Engine emission system failure Tier4 icon now follows FMI levels and SPN3349 set to 7 for protocols with 10 ms transmission rate.

Corrections:

  • Menu 6231 for GB close delay is no longer available when the application is power management.
  • Corrected that strange texts sometimes were shown in the USW log.
  • "L-L and P total" view now shows the correct value.
  • Power factor set point on Modbus is now correctly initialized after power-up.
  • General improvements to the D550/DVC 550 integration module.
  • Ph-ph voltage will not saturate before the hardware limit is reached.
  • Correct behavior of dfdt is now ensured when the number of periods are set above 12.
  • The variable needed for angle check in Q dep U< alarm is updated.

1.05.4

06/04/2021

PM compatibility: 1.22.0.

Corrections:

  • HYBRID: When reconfiguration of the RS-485 ports, power cycle of the unit is no longer needed.
  • HYBRID: The unit is now able to automatically switch between Sunspec addresses (40000, 50000 and 0). If Sunspec initialization is not compatible, reinitialization starts in 20 seconds.

1.05.3

02/03/2021

PM compatibility: 1.22.0.

Corrections:

  • Secured mode now works when Fuel optimisation is in use.
  • Priority update now works when more than 16 gensets or more than 16 mains are present in a plant configuration.
  • PMS priority data is properly maintained internally in all genset controllers.
  • When digital input 50 is not used as feedback, it is no longer disturbing the check of breaker status.
  • Breaker feedbacks are properly updated on the I/O status and the I/O setup page.

1.05.2

06/01/2021

PM compatibility: 1.22.0.

Corrections:

  •  Support is added for Volvo engine with 60 Hz as primary speed when Volvo proprietary engine speed is used.
  •  Generator under-frequency and under-voltage alarms are now inhibited during idle run.

1.05.1

08/12/2020

PM compatibility: 1.22.0.

Corrections:

  •  AGC 150 Hybrid controller got stuck in Sunspec initialize, due to a previously unknown Modbus model in the ABB PVS175 PV inverter.
  •  Transmitting DVC 550/D550 parameters over the CAN was irregular. This is corrected.

1-05-0

30/11/2020

PM compatibility: 1.22.0.

New features:

  • Support for the new input configuration interface.
  • DVC 550 PT100 measurements in display and selection in delta alarms.
  • EIC start/stop as a parameter.
  • M-Logic to start DG and close/inhibit close GB in auto mode. M-Logic to inhibit TB close.
  • Scania EMS2 S8 Engine I/F.
  • Configurable spinning reserve request using parameter 8930, not supported in BTB applications.
  • Ground breaker to CORE package
  • Shutdown override as new inhibit.
  • Parameter to use nominal frequency or rpm as reference for EIC speed offset.
  • Support for Volvo Penta EMS2.4.
  • New combined views with electrical data.

Changes:

  • Configurable multi inputs and new DM1 telegrams for JCB LiveLink. 
  • Racked out breaker On/off displayed in log.
  • Minimum level of "Frequency detection level (6165)" changed from 20hz to 10hz. 

Corrections:

  • Ground relay routine improved:
          - There is now always an overlap when transferring ground relays between DGs.
          - The best DG to hold the ground relay now keeps it closed during de-load and transfer of the ground relay happens when the de-loading DG is ready to open its GB.
          - Older versions with ground relay enabled are no longer compatible going forward.
  • AGC 150 Read log freezes controller. 
  • Phase calculations are now properly performed and transmitted to the DVC 550 & D550 when changed through M-Logic.
  • AC configuration in the D550/DVC 550 is now controlled by the AGC.
  • When configured for split phase operation, the nominal voltage setpoint is now correctly calculated for the DVC 550/D550.
  • New parameter #7746 DAVR AC config is introduced. This helps fix situations where the DAVR is not able to follow the AC configuration of the AGC.
  • Configuring a mains standalone application with the CAN bus set to OFF in the application configuration prevented the MB from closing. This has been corrected.
  • If a DG was running with its GB open and ground relay closed, and a mains then connected to the busbar, the ground relay would open. This has been corrected.
  • Alternative engine speed control for Volvo protocols including counter and checksum is added. Can be enabled with the new parameter 15110.
  • LTO now works correctly when unit is STAND-ALONE (non-sync).
  • Multi input alarm level 2 Min/Max now updates correctly when output limits are changed from multi input configuration in USW.

1-04-2

22/09/2020

PM compatibility: 1.17.2.

Corrections:

  •    TEST type in StandAlone (option S1) is limited to SIMPLE TEST.
  •    Limit evaluation of multi-input 23 alarm for use in M-Logic is now working.
  •    Included CAN Start/Stop in the Hatz proprietary CM1 telegram.
  •    Current handling of TIER 4 icons for the Hatz protocol.
  •    Read Aftertreatment 1 Intake Gas telegram for the Hatz protocol.
  •    Necessary to force a regeneration until current feedback is received from ECU.
  •    Fuel optimization + running hours does not swap DG's at fixed load.

1-04-1

29/07/2020

Version 1.04.1 based on 1.04.0

PM compatibility: 1.17.2

Corrections:

  • Errors regarding powermanagement applications with PV, ASC and battery controller corrected.

1.03.1

14/05/2020

PM compatibility: 1.17.2.

Corrections:

  • Analog output limits for the transducer output are corrected.
  • Transducer input range is extended on multi inputs to support the setup of limits corrected in #1.
  • STOP button has always a lid on the genset when running German rule, V0108.

1.03.0

03/04/2020

PM compatibility: 1.17.2

New features:

  •    DVC 550 and D550 are now supported by the AGC.
  •    Configurable amount of units for triggering Fatal CAN Error alarm, added in menu 8800.

Changes:

  •    Emulated value for I>> alarms added.
  •    Easy Connect is no longer blocking DG start in single DG applications.

Corrections:

  •    In AMF situations where the mains had no TB, and #7065 mains fail ctrl was set to "Start engine" and the DGs had to connect through a BTB to supply the mains, the MB would not open as it did not have information about whether or not the DGs Hz/V OK timer had run out. And as the MB would not open the BTB would not close resulting in a deadlock. This has been corrected.
  •    TB power capacity overrule timer will now run if there is an active MB trip failclass or the MB cannot be closed.
  •    Ring bus applications: If BTBs were closed at and under application configuration, opening a BTB could cause a DG to start without a proper start signal.
  •    Fixed a situation where opening a semi BTB, in a plant with an active start signal, would cause a DG to briefly engange its start prepare relay.
  •    In a plant where all DGs are divided by open BTBs, if for example, DG1 is running and needs help from DG2, DG2 would start and close its breaker, then synchronize the BTB, and as the BTB would close, DG3 would briefly engange its start prepare relay. This has been fixed.
  •    PMS + ISLAND + SEMI + GUIDED MIMIC: Start/stop buttons LED visible when relevant on genset.

1.02.0

26/03/2020

PM compatibility: 1.17.0.

New features:

  •    Two new EIC aftertreatment alarms have been added: "High SOOT warning" and "High SOOT shutdown".

Changes:

  •    Vector jump, df/dt, positive busbar sequence and directional over-current are now available in CORE MAINS and CORE BTB.
  •    New TIER 4 icons for JCB EIC are added.

Corrections:

  •    Parameter handling could in special cases cause decimals to be handled incorrectly in the display menu. This is corrected.
  •    Problems with freeze and white screen are now prevented.
  •    Analogue values from CIO 308 are now shown correctly in view-lines.
  •    JUMP menu causing unwanted parameter change is corrected.
  •    JUMP menu freeze is now prevented.
  •    Overspeed 2 menu (4520) is now shown correctly.
  •    GUIDED mimic is corrected with external breaker, so GB ON/OFF buttons do not lit up.

1.01.0

19/12/2019

PM compatibility: 1.17.0.

New features:

  • EIC: JCB J1939 protocol is added.
  • EIC: DEF level shown on lower tiny line in measure views. 
  • Stand Alone (option S1) is implemented. Breaker selection is extended with 'No breaker' and 'External breaker'.
  • LED colors can now be changed. An option to select a different LED color behavior in parameter 6084.
  • Now it is possible to change the source address for PGN GC1 and CM1 independently of each other for all engine protocols.

Corrections:

  • BTB can now be part of a plant with CORE units.

1.00.3

22/10/2019

PM compatibility: 1.17.0

Corrections:

  • External BTB position feedbacks are now working again.
  • Phase sequence error alarms are now working 3W3 coupling.
  • Service timers can now be reset.
  • Translated texts for I/O texts in Service View are now shown correctly.

1.00.2

05/08/2019

Version 1.00.2 based on 1.00.1

PM compatibility: 1.17.0

Corrections:

  •    Deloading the TB is now properly handled in test mode when parameter #8273 "Deload TB back sync." is enabled
  •    Multi inputs could go into overflow when set to voltage type
  •    Internal analog outputs (52/55) now works correct when used with GP PID.
  •    Genset priority would update even though the user had not issued an update.
  •    If mains ATS is active, and TB is closed onto a healthy busbar, and the controller is powercycled, the TB no longer opens and closes on power up.
  •    When sending a stop command during idle start the idle relay is kept closed.
  •    Fixed situations where multi start would not work correctly in ISLAND and AMF applications.
  •    M-Logic flag "Run all available island DG's" starts all DG's when activated.
  •    Mimic for BTB and MAINS with External breaker updated, so the respective buttons (open/close) are not visible.
  •    Various parameters added to parameter tree
  •    Improved Easy Connect functionality:
          - Rapid menu changes prevented
          - Info text on removed units
          - Possibility to remove the other unit with pop-up when only 2 in plant
          - Better handling of fault situations (Appl. hazard or Duplicate CAN ID)
          - Removed units are no longer blocked from running
          - Faster indication of changes on the other units

1.00.0

30/04/2019

PM compatibility: 1.17.0

  • Initial release

On this page, you can download software updates for your product(s) and help yourself to various utility tools and add-ons that will assist you in setting up, detecting faults and configuring your product(s).

Please be advised that not all of our products can be updated by the user. Nor do all of our products come with a utility tool. Consequently, the list on this page cannot be considered an overview of our product programme.

DEIF will register your download along with the used e-mail address for the purpose of sending out information on future updates, if requested.

DEIF cannot be made responsible for any consequences of failed product updates or use of utility tools. Nor can DEIF A/S be made responsible for consequences of changes in behaviour of products due to a software upgrade. It is always the responsibility of the user to ensure correct set-up and configuration before commissioning. Please study the version log of the software before updating the product.

Licence agreement for software downloaded from www.deif.com

Downloaded software remains the property of DEIF. The software may not be distributed for commercial purposes, changed or reused in full or in part or sold to any third parties.

The latest versions for full functionality

As always, we recommend that you install our offered improvements to fully utilise your DEIF product.

All improved software can be downloaded at your convenience at www.deif.com under “Software”.

Should you have any questions or experience problems finding the relevant software for your product, please feel free to call DEIF A/S at +45 96149614 or your relevant local DEIF office. Alternatively, we are always ready to assist you, if you send an e-mail to support@deif.com.