Multi-line 2 ASC Application Software series 4.x

このソフトウェアは以下のDEIF製品に適用されます。

ダウンロードされようとしています 4.11.0

最終版以降に行われた主な変更は以下の通りです。

PM compatibility version 1.16.0

New features:

  • Support of KStar inverter. 
  • Weatherstation support added. 
  • Support of PV and Mains power meter input in M-logic.
  • Support of Modbus based power readings from all DEIF controllers.
  • Support of ABB Trio 50 inverter. 
  • Support of GoodWe MT-series inverter. 
  • Support of Huawei SUN2000 55-60KTL inverter.
  • Support of Huawei SUN2000 90-105KTL inverter.
  • Support of APS PMU-100 energy meter.

Corrections:

  • Ginlong Solis protocol corrected.
  • Spinning reserve is now using the actual production. 

 

バージョン 日付 説明

4.11.0

11/12/2018

PM compatibility version 1.16.0

New features:

  • Support of KStar inverter. 
  • Weatherstation support added. 
  • Support of PV and Mains power meter input in M-logic.
  • Support of Modbus based power readings from all DEIF controllers.
  • Support of ABB Trio 50 inverter. 
  • Support of GoodWe MT-series inverter. 
  • Support of Huawei SUN2000 55-60KTL inverter.
  • Support of Huawei SUN2000 90-105KTL inverter.
  • Support of APS PMU-100 energy meter.

Corrections:

  • Ginlong Solis protocol corrected.
  • Spinning reserve is now using the actual production. 

 

4.10.1

16/04/2018

Corrections:

  • Menu 2150, "Phase Sequence Error" was missing at ASC Solar.

4.10.0

20/03/2018

PM compatibility version 1.16.0

New features:

  • Battery variant
  • Support of SolarEdge inverter
  • Support of Tesla PowerPack inverter 
  • Support of Qinous inverter
  • Support of Vacon8000 inverter
  • Support of Chint 50/60 kW inverter 
  • Support of Chint 14/36 kW inverter 
  • Support of SolidQ 50 inverter
  • Support of SolidQ 60 inverter
  • Support of 16 ASCs, in ID range 25-40
       

Corrections:

  • Power management total power and reactive power readings in Modbus always displayed 0.
 

4.05.2

12/01/2018

Corrections:

  • Schneider iEM3000 protocol corrected.

4.05.1

02/01/2018

PM compatibility version 1.15.0

Corrections:
1- Fail classes initialised to "Shutdown" unintendedly.

 

4.05.0

30/11/2017

PM compatibility version 1.15.0

New features:

  • Support of 16 mains energy meter.
  • Support of Socomec Multis L40 energy meter.
  • Support of EDS MMT3(5A) energy meter.  
  • Support of Gossen mavalog energy meter.
  • Support of EDMI energy meter.
  • Support of calculated PF and kVA based on energy meter data. 
  • Support of Reuniwatt SkyInSight.
  • Support of Ginlong Solis inverter.

Corrections:

  • The ASC will not try to close after it is tripped due to under-voltage coil.

Changes:

  • Socomec Multis L40 changed to Socomec Diris a40. 
  • Generic SunSpec protocol updated. Unknown maker specific models no longer interpreted by the ASC as SunSpec map being incompatible.

 

4.04.0

05/10/2017

PM compatibility version 1.15.0

New features:

1- Support of HiQ inverter.
2- Support of IngeTeam inverter.
3- Support of Schneider PM5560 energy meter.
4- Support of Socomec Multis L40 energy meter.

4.03.1

09/05/2017

PM compatibility version 1.15.0

Corrections:

  • Correction to “Re-initialisation of PV inverter protocol made robust”.
  • PV Monitoring functionality malfunctioning in SunSpec protocol.

4.03.0

03/04/2017

Version 4.03.0
PM compatibility version 1.15.0

New features:

  • Support of short-term weather forecast system, SteadyEye, from SteadySun.

Changes:

  • "SMA SunSpec" protocol selection text changed to "SMA SunSpec v2.82". 

Corrections:

  • Re-initialisation of PV inverter protocol made robust.
  • PV curtailment "Yearly" counter displayed garbage.
 

4.02.0

21/12/2016

PM compatibility version 1.15.0

New features:

  • Support of Modbus-based power meters.
  • Support of DG and mains power readings via DEIF open protocol.
  • Support of GB/MB breaker feedbacks via M-Logic.
  • Support of INVT BG series inverter.
  • Mains kWh counters added.

Changes:

  • Option M4 made optional

Corrections:

  • Delta RPI interface corrected.
  • PV monitoring data could not be read via service port or H2.
  • MBON status not working in M-Logic.
  • Minimum genset load could not be accessed if Option G5 is not present.
  • Minimum genset load setting control from M-Logic did not work

このページではお使いの製品のソフトウェアアップデートをダウンロードでき、また設定、不具合の検出、製品の構成を支援する様々なユーティリティーツールおよびアドオンを入手できます。

ユーザーは当社製品のすべてをアップデートできないことにご注意ください。また、当社製品のすべてにユーティリティーツールが備わっているわけではありません。このため、このページのリストを当社の製品プログラムの概要とみなすことはできません。

DEIFはお客様のダウンロードとご使用になられたEメールアドレスを今後のアップデートのお知らせをお送りする目的で、リクエストがあれば登録いたします。

DEIFは製品アップロードまたはユーティリティーツールの使用の失敗によるいかなる結果に対しても責任を負いません。また、DEIF A/Sはソフトウェアアップデートにより製品の動作に起こる変更の結果に対する責任を負いません。試運転前に正しい設定と構成を確実に行うのは、常にユーザーの責任です。ソフトウェアのバージョンログを確認してから製品のアップデートを行うようにしてください。

www.deif.comからダウンロードしたソフトウェアのライセンス契約

ダウンロードしたソフトウェアはDEIFの財産であり続けます。本ソフトウェアを商用目的で配布したり、全部または一部を変更または再利用したり、第三者に売却してはなりません。

いつもながら、当社が提供する改良点をインストールしていただき、お使いのDEIF製品を最大限に活用していただくことを推奨いたします。

すべての改良ソフトウェアはご都合の良い時に、無料で www.deif.com にて、「ソフトウェア」、次に「ソフトウェアダウンロード」に進むことでダウンロードできます。

お使いの製品の関連ソフトウェアを見つける際に質問または問題がある場合は、お気軽にDEIF A/S (+45 96149614)までお電話されるか、または関連の最寄りのDEIF営業所までお電話ください。あるいは、support@deif.com.までEメールをお送りいただければ、常にお客様をサポートさせていただきます。

プレスリリース、2015年6月

特に「旧式」DEIF A/S ML‐2製品に関連する製品改良.