Multi-line 2 ECU 100 Application Software series 1.xx

このソフトウェアは以下のDEIF製品に適用されます。

ダウンロードされようとしています 1.02.1

最終版以降に行われた主な変更は以下の通りです。

Changes:

  • When M-Logic cooldown threshold is selected, it will be used regardless if parameter 6214 is 0.
  • Improved RPM measurement.

Corrections:

  • EIC alarms used as low alarms would appear when the CAN communication was lost.
  • Idle run could cause external start not to work.
  • Running hour counter offset could be adjusted to more than 99999 hrs.
  • Engine could end up in an infinite state between crank and running detection.
  • Alarms added to prevent this:
    - Running detection reached timer (parameter 6351)
    - External engine stop detection (parameter 6352)

バージョン 日付 説明

1.02.1

15/03/2016

Changes:

  • When M-Logic cooldown threshold is selected, it will be used regardless if parameter 6214 is 0.
  • Improved RPM measurement.

Corrections:

  • EIC alarms used as low alarms would appear when the CAN communication was lost.
  • Idle run could cause external start not to work.
  • Running hour counter offset could be adjusted to more than 99999 hrs.
  • Engine could end up in an infinite state between crank and running detection.
  • Alarms added to prevent this:
    - Running detection reached timer (parameter 6351)
    - External engine stop detection (parameter 6352)

1.02.0

03/02/2016

New features:

  • Contrast offset added in parameter 9152.
  • PT 1000 sensors introduced in multi-input 6 and multi-input 7.
  • Several events and limits added to M-Logic.
  • Added one additional battery low alarm (parameter 4950).
  • Inhibits can be set in battery low/high menu (parameter 4950/4960/4970).
  • Oil renewal feature introduced.
  • Battery voltage column now available in every entry in the log information in the DEIF Utility Software.
  • Added three freely translatable texts in the view lines.
  • Added support of ADEC CAN open, shutdown override.
  • Added EIC manual speed regulation

 

Changes:

  • Multi-inputs made linear in application emulation.
  • Extended maximum limit in start on time, parameter 6183.
  • Extended fuel fill check timer (parameter 6553).
  • Made it possible to enable/disable fuel fill check (parameter 6553).
  • Made it possible to use auto acknowledge on Ext. Comm. Error parameter.
  • Start attempt maximum limits changed. Extended stop timer minimum limit changed.
  • Language translation changed. From now on it is not possible to select a different font. The two fonts are now merged together, and containing all previously used characters. New characters are added. If any unsupported signs are written to the device, the signs will appear as ' ' (space).
  • Three RMI sensor curves added. One for each RMI type.  It will be possible to choose them in channel 10460, 10630 and 10800 by selecting "Sensor type 4" in the DEIF Multi-line 2 Utility Software v.3.

Corrections:

 

  • Stop coil did not activate when start sequence was aborted.
  • Corrected missing digit to running hours.
  • Sign of display values between -1.0...0.0 with one or two decimals shown correct.
  • Missing EIC values in analogue delta alarms added.
  • Measurement through the MPU input caused periodical peaks in the RPM measurement,  which could cause an unwanted trip of the generator breaker.
  • M-Logic line combination misinterpretation corrected.
  • Application emulation couldn't start properly with breaker and engine commands selected as inactive.
  • PT sensor offset parameters now corrected to compensate for the cable resistance.
  • Unit and MTU ADEC(SAM) communication not started during certain power supply situations - corrected. (Updated correction to avoid start request after communication has been reestablished).
  • M-Logic command "Start and Close GB" was ignored during cool down.
  • SCANIA EMS2 correction of start/stop.
  • Clock synchronise over Modbus was causing the service timer to offset its current timer value - corrected.
  • Configuration of output relays corrected, so all functions can be connected to all available relays.
  • Selection of multi-inputs for fuel pump logic corrected.
  • Fuel pump relay could activate at power-up of the controller before fuel level measurement has settled.
  • Several Modbus (option H2) addresses were not working - corrected.
  • MTU MDEC 302/303 protocols battery voltage measurement corrected.
  • Idle run timer now resets at each start attempt.
  • Nominal RPM now available to configure.
  • Hz/V failure group 4560 is removed.
  • Unit could reboot if a Modbus command was sent while 'Inhibit modbus commands' was active
  • Running hour counter could reset unintendedly - corrected.
  • Running hour counter could reset unintendedly at power cycle - corrected.
  • Scania EMS2 KWP2000 log clear now possible.
  • Exhaust gas temperature - right/left was not shown correctly in display.
  • Storage of service timer values during reset corrected.
  • Relays could activate under boot sequence - corrected.

1.01.0

23/02/2015

New features:

  • Common alarm
  • Siren

Changes:

  • Relay 3 default setting changed from Horn to Not used

Corrections:

  • The functionality of not showing alarm in case of combination of the alarms used in relays has been corrected
  • Idle run activation through digital input and reactivation after stop button functions have been corrected
  • Idle run function corrected

1.00.2

01/09/2014

Corrections:

  • Relay channel error after power up corrected
  • Parameter 3410 password corrected
  • MTU Smart Connect engine protocol updated

1.00.1

26/11/2013

1.00.0

01/05/2013

  • First release

このページではお使いの製品のソフトウェアアップデートをダウンロードでき、また設定、不具合の検出、製品の構成を支援する様々なユーティリティーツールおよびアドオンを入手できます。

ユーザーは当社製品のすべてをアップデートできないことにご注意ください。また、当社製品のすべてにユーティリティーツールが備わっているわけではありません。このため、このページのリストを当社の製品プログラムの概要とみなすことはできません。

DEIFはお客様のダウンロードとご使用になられたEメールアドレスを今後のアップデートのお知らせをお送りする目的で、リクエストがあれば登録いたします。

DEIFは製品アップロードまたはユーティリティーツールの使用の失敗によるいかなる結果に対しても責任を負いません。また、DEIF A/Sはソフトウェアアップデートにより製品の動作に起こる変更の結果に対する責任を負いません。試運転前に正しい設定と構成を確実に行うのは、常にユーザーの責任です。ソフトウェアのバージョンログを確認してから製品のアップデートを行うようにしてください。

www.deif.comからダウンロードしたソフトウェアのライセンス契約

ダウンロードしたソフトウェアはDEIFの財産であり続けます。本ソフトウェアを商用目的で配布したり、全部または一部を変更または再利用したり、第三者に売却してはなりません。

いつもながら、当社が提供する改良点をインストールしていただき、お使いのDEIF製品を最大限に活用していただくことを推奨いたします。

すべての改良ソフトウェアはご都合の良い時に、無料で www.deif.com にて、「ソフトウェア」、次に「ソフトウェアダウンロード」に進むことでダウンロードできます。

お使いの製品の関連ソフトウェアを見つける際に質問または問題がある場合は、お気軽にDEIF A/S (+45 96149614)までお電話されるか、または関連の最寄りのDEIF営業所までお電話ください。あるいは、support@deif.com.までEメールをお送りいただければ、常にお客様をサポートさせていただきます。

プレスリリース、2015年6月

特に「旧式」DEIF A/S ML‐2製品に関連する製品改良.